Bear Cub 750 PSV Ventilator

Viasys

609-388-4635 ext. 223

(No reviews yet) Write a Review

No Interest if paid in 6 months on purchases of $99+

SKU:
Bear Cub 750 PSV
Condition:
Refurbished
Weight:
75.00 LBS
Shipping:
$125.00 (Fixed Shipping Cost)

Product Description

The Bear Cub 750vs infant ventilator is designed to accommodate a range of patients from the small neonate to the 30kg pediatric. The Bear Cub 750vs and 750psv Infant Ventilators are designed to provide ventilator support for the critical care management of patients ranging from the small neonate (500 grams or larger) to the small pediatric patient (up to 30 kg) with compromised lung function.   The 750vs has integrated synchronized ventilation and tidal volume monitoring.  It also includes independent base & inspiratory flows and an internal battery back-up.

 

FEATURES:

  • Integrated Synchronized Ventilation
  • Tidal Volume Monitoring
  • Independent Base & Inspiratory Flows
  • Internal Battery Back-Up
  • Exclusive Volume Limit
  • Assist Control
  • Flow Cycled AC
  • SIMV/IMV
  • Flow Cycled SIMV
  • CPAP
  • SIMV with Pressure Support
  •  

    SPECIFICATIONS:

    Controls

    • Mode: AC, Flow cycle AC, SIMV/IMV, Flow Cycled SIMV, SIMV/PSV, PSV, CPAP
    • Ventilator Rate: 1.0 to 150 BPM
    • Inspiratory Time: 0.1 to 3.0 sec.
    • Inspiratory Flow: 1.0 to 30 LPM
    • Base Flow: 1.0 to 30 LPM
    • Volume Limit: 5.0 to 300 ml
    • PEEP: 0 to 30 cmH2O
    • Inspiratory Pressure: 0 to 72 cmH2O
    • Manual Breath: x One
    • Assist Sensitivity: 0.2 to 5.0 LPM; Minimum to Maximum bar
    • Over Pressure Relief: 15 to 75 cmH2O
    • % O2: 21 to 100%
    • Alarm Loudness: Min 60 to Max. 75 dbA
    • Audible Off Volume Limit: LED On/Off

    Alarms

    • High Breath Rate: 3.0 to 255 BPM
    • Low PEEP/CPAP: -5.0 to 30 cmH2O
    • Low Inspiratory Pressure (vs): 1.0 to 65 cmH2O
    • Low Inspiratory Pressure (psv): 5 to 41 cmH2O (derived from High Pressure Limit and Low PEEP/CPAP Alarm Settings
    • Patient Circuit: LED On/Off
    • Failed to Cycle: LED On/Off
    • Low Gas Supply: LED On/Off
    • Apnea Alarm: 5, 10, 20, 30 sec
    • Settings Incompatible: LED On/Off
    • Pressure Settings Incompatible: LED On/Off
    • Prolonged Inspiratory Pressure: LED On/Off
    • Flow Sensor: LED On/Off
    • Low Battery: LED On/Off
    • Alarm Silence: 60 sec
    • Visual Reset: Push Button
    • High Pressure Limit: 10 to 75 cmH2O
    • Low Minute Volume: Off to 99 lpm

    Monitors

    • PEEP: 0 to 30 cmH2O
    • Breath Rate: 0 to 255 BPM
    • Breath Type (Patient Initiated): LED
    • Minute Volume: 0 to 30.0 LPM
    • Tidal Volume (Exhaled): 0 to 500 ml
    • % Tube Leak: 0 to 100%
    • Inspiratory Time: 0.1 to 3.10 sec Expiratory Time 9 to 99.9 sec
    • I:E Ratio: 9.9:1 to 1:9.9
    • Peak Inspiratory Pressure: 0 to 99 cmH2O
    • Mean Airway Pressure: 0 to 75 cmH2O
    • Air Pressure: 0 to 100 psig; 0 to 99 psig
    • O2 Pressure: 0 to 100 psig; 0 to 99 psig
    • Proximal Airway Pressure: -10 to 100 cmH2O
    • Hour meter: 0 to 99,999 hours
    • Test: Push Button
    • Line Power: Green/Red LED
    • Battery: LED On/Off
    • Inspired Tidal Volume: 0 to 500 ml

    Limits to Ventilation (Fixed)

    • Minimum Expiratory Time: 0.15 seconds
    • Maximum Inspiratory Time: 3:10 seconds
    • Maximum settable I:E Ratio: 4:1

     

     

    TOLERANCES:

     

    Monitors

    • Breath Rate: ± 1 BPM or ± 20 msec, whichever is greater
    • Inspiratory Time: ± 0.02 sec
    • Expiratory Time: ± 0.02 sec
    • I:E Ratio: ± 0.1 or ± 20 msec (on the calculation based on the monitored inspiratory and expiratory times), whichever is greater
    • Airway Pressure (Continuous):
      ± 1 cmH2O (-10 to 20 cmH2O)
      ± 2 cmH2O (20 to 65 cmH2O)
      ± 3 cmH2O (65 to 100 cmH2O)
    • Peak Inspiratory Pressure: ± 2 cmH2O or ± 5%, whichever is greater
    • Mean Airway Pressure: ± 2 cmH2O or ± 3%, whichever is greater
    • PEEP: ± 2 cmH2O or ± 5%, whichever is greater
    • Air/O2 Pressure: ± 5 psig
    • Minute Volume Accuracy: Based on the Tidal Volume and Breath Rate Monitors
    • Inspiratory Tidal Volume: ± 1 ml or ± 10%, whichever is greater
    • Expiratory Tidal Volume: ± 1 ml or ± 10%, whichever is greater
    • % Leak: ± 1 ml or ± 2%, whichever is greater
      (when compared to the Inspired and Expired Tidal Volume Monitors)
    • Hour Meter: ± 2% of reading

    Alarms/Limits

    • Low PEEP/CPAP: ± 2 cmH2O
    • High Breath Rate: ± 1 BPM
    • Low Minute Volume:
      ± 10 ml/min (0 to 99 ml/min)
      ± 0.1 L/min (0.1 to 9.9 L/min)
    • High Pressure Limit: ± 4 cmH2O
    • Prolonged Inspiratory Pressure: ± 2 cmH2O
    • Volume Limit: ± 2 ml or ±  10% of setting, whichever is greater
    • Apnea: ± 1 sec
    • Maximum (Pop-off) Pressure: ± 4 cmH2O

    Controls

    • Ventilator Rate: ± 1 BPM or ± 20 msec (applied to the breath interval), whichever is greater
    • Inspiratory Rate:
      ± 0.020 sec (0.10 to 0.50 sec)
      ± 0.025 sec (0.50 to 3.00 sec)
    • Assist Sensitivity: Not a calibrated scale
    • PEEP/CPAP and Inspiratory: ± 1 cmH2O or ±  5%, whichever is greater (breath to breath)
    • Base/Inspiratory Flow: ± 0.5 LPM or ± 10% of setting, whichever is greater (0 to 60 cmH2O)
    • Oxygen %: ± 3%
    • Degree of Safety in Presence of Flammable Anesthetics: None
    • Mode of Operation: Continuous
3 month