GE Versamed 201i Ventilators

GE

Contact us at 609-388-4635 ext. 223

(No reviews yet) Write a Review

No Interest if paid in 6 months on purchases of $99+

SKU:
Versamed201i
Condition:
Refurbished
Weight:
25.00 LBS
Unit includes:
Stand
Model Number::
IC/AB

GE 201i Brochure PDF Download

The GE Versamed 201i Ventilator

With its comprehensive list of standard features, including the latest modes of ventilation, the iVent201 is appropriate for all levels of patient acuity, from pediatric through adult, and in all care settings, from the patient’s bedside to transport to another point of care.

With its highly featured transport capability and rugged construction, the iVent201 takes ICU ventilation outside of the confines of the hospital. Optimized NIV and the Adaptive Bipap help caregivers maximize patient comfort and synchrony. 

Basic Description

  • Electrically powered, computer controlled ventilator
  • Closed loop flow & pressure controller
  • Ventilation modes:
    • Assist control (A/C):
      • Volume controlled
      • Pressure controlled
    • Synchronized intermittent mandatory ventilation (SIMV):
      • Volume controlled
      • Pressure controlled
    • Continuous positive airway pressure (CPAP)
    • Pressure support ventilation (PSV)
  • Special features:
    • Adaptive Bi-Level* (NIV)
    • Preset parameters by patient weight
    • Apnea backup ventilation
    • Adjustable rise time
    • Easy Exhale*
    • Sigh breath
    • 100% O2 suction

Ventilation Performance and Controlled Parameters

  • Respiratory rate: 1 to 80 bpm
  • Tidal volume: 50 to 2,000 ml
  • Inspiratory pressure limit: 5 to 80 cm H2O
  • Inspiratory time: Adaptive I-Time* or 0.2 to 3 sec
  • Esens: 10-90%
  • Rise time: Mid/high/max/auto
  • Peak flow: Adaptive Flow* or 1 to 120 L/min; Spontaneous up to 180 L/min
  • Oxygen mix (FiO2): 21 to 100%
  • PEEP: 0 to 40 cm H2O
  • Trigger sensitivity: 1 to 20 L/min flow sensitivity –0.5, to –20 cm H2O pressure sensitivity
  • PSV: 0 to 60 cm H2O
  • Positive pressure relief valve: 80 cm H2O
  • Synchronized nebulizer: 5 to 240 min

Monitoring and Displayed Parameters

  • Airway pressure (analog bar graph & numerical)
  • Total breath rate
  • I:E ratio
  • Exhaled tidal volume
  • Exhaled minute volume
  • Peak flow
  • Inspiratory time
  • Electrical power source (AC/external DC/internal DC)
  • Battery level
  • Pressure, flow and volume Waveforms software package:Trending of monitored data (72 hours)
    • Real-time pressure and flow waveforms
    • Waveform history brows
  • Respiratory mechanics (C, R, MAP, RR/Vt)SpO2
    • Pressure, flow and volume loops

User Adjustable Alarms

  • Respiratory rate (high/low)
  • Minute volume (high/low)
  • Pressure (high/low)
  • Low Vt (15 to 85%)
  • SpO2 (high/low)
  • HR (high/low)
  • Apnea time (0 to 120 seconds)
  • FiO2 (high/low)
  • Leak (0 to 100%)

Additional Alarms:

  • Inverse I:E ratio
  • Low O2 pressure
  • AC disconnect
  • Low/Empty battery
  • Over temperature
  • Service notice
  • Patient disconnect
  • Check sensor
  • High PEEP
  • Battery disconnected / damaged
  • Sensor disconnect  

Additional Indicators:

  • Alarm silence icon and timer
  • Breath type icon
  • Internal battery use
  • Date and time
  • Hour meter
  • Battery charge level
  • Need calibration
  • LED: On, charge, alarm
  • Nebulizer status indicator

Power Supply

  • External AC: 100 to 240 V, 50 to 60 Hz, Max 1.6 A
  • External DC: 12 to 15 V, Max 8.5 A
  • Internal battery: Sealed lead-acid 12 V (7.8 Ah) (rechargeable)
  • Operating time: Depending on ventilator settings and impedance – standard internal up to 2 hours, optional extended internal up to 4 hours and optional external up to 8 hours.

Oxygen (Enrichment) Supply

  • High pressure supply: 40 to 75 psi (2.8 to 5.1 bar)
  • Low pressure: Max 15 L/min or 0.5 psi   

External Interface

  • Remote monitor (VGA)
  • RS-232 serial port, 9 pin
  • DIN keyboard connector
  • RJ11 remote alarm connector

Environmental Specifications

  • Operating temperature: 0 to 50° C/32 to 120° F
  • Storage temperature: –15 to 70° C/–4 to 140°F
  • Relative humidity: 15 to 95% at 30° C/85° F
  • Water/dust resistance: IP54 (splash proof)
  • Atmospheric pressure: 430 to 825 mm Hg (15,000 feet)
  • Vibration:
    • IEC 68-2-6 and IEC 68-2-34
    • MIL-STD-810E
  • Shock:Total external sound level: 40 to 45 dBa at one meter
    • IEC 68-2-27 (100 g)
    • MIL-STD-810E

Standards and Safety Requirements:

Meets the Requirements of:

  • ASTM F1246-91
  • CSA C22.2 No. 601.1/601.2
  • UL 60601.1
  • EN/IEC 60601-1
  • EN/IEC 60601-1-2
  • EN/IEC 60601-2-12
  • EN 794-3
  • ISO 10651-2/3
  • EN/IEC 60601-1-6
  • EN/IEC 60601-1-8
2. These units are Intensive Care models with Adaptive Bi-Level Mode
3 month