Refurbished Respironics BiPap Vision
Operator's Manual PDF Download
FEATURES
Integrated Display Screen
Integrated Display Screen displays easy-to-read real time graphics in waveform or bar scale format, providing the following measured and calculated numerical values to assist with ventilator management:
- IPAP
- Total Breath Rate
- Exhaled Minute Ventilation
- % Patient Triggered Breaths
- Exhaled Tidal Volume
- EPAP
- Ti/Tot
- Peak Inspiratory Pressure
- Patient or Total Leak
ModesOxygen Control up to 100%
- PAV * /T (Proportional Assist Ventilation/Timed mode) helps to promote improved patient comfort and enhanced patient/ventilator synchrony through independent adjustment of Volume and Flow assist based on the patients disease state.
- Allows you to blend oxygen within the unit in concentrations ranging between 21-100% without auxiliary oxygen tubing attached to the mask.
Pressure Regulation at the Mask
- Pressure regulation at the mask allows you to regulate pressure therapy to assure delivery where it counts (not inside the machine), and automatically adjusts for variations.
Upgradeable Design Provides Flexibility
- Upgradeable features provide flexibility in your purchase decision, now and in the future. The Vision System gives you the ability to upgrade instead of buying a new machine for each medical revolution.
BiPAP® Auto-Trak SensitivityTM
- Optimum Response Automatically. The innovative development of Auto-Trak SensitivityTM enables the BiPAP Vision System to automatically respond to changing breathing patterns and circuit leaks by identifying leaks and adjusting variable sensitivity thresholds for optimum response with every breath.
SPECIFICATIONS
Control Ranges and Increments: Parameters
Parameters | Control Range | Control Increment |
IPAP | 4 to 40 cm H2O | 1 cm H2O |
EPAP | 4 to 20 cm H2O | 1 cm H2O |
CPAP | 4 to 20 cm H2O | 1 cm H2O |
Rate | 4 to 40 BPM | 1 BPM |
Timed Inspiration | 0.5 to 3.0 sec | 0.1 sec |
IPAP >Rise Time | 0.05 to 0.40 sec | 4 set points: .05, .1, .2, .4 sec |
Oxygen Concentration (%O2)* | 21 to 100% | 4% from 21 to 25% 5% from 25 to 100% |
*With optional Oxygen Module
Control Ranges and Increments: Alarms
Alarm | Control Range | Control Increment |
High Pressure | 5 to 50 cm H2O | 1 cm H2O |
Low Pressure | Disabled;0 to 40 cm H2O | 1 cm H2O |
Low Pressure | Delay 0 to 60 sec | 1 sec |
Apnea | Disabled; 20 to 40 sec | 4 set points: Disabled, 20, 30, 40 sec |
Low Minute Ventilation | Disabled; 1 to 99 L/min | 1 L/min |
High Rate | 4 to 120 BPM | 1 BPM |
Low Rate | 4 to 120 BPM | 1 BPM |
Display Ranges and Increments
Parameters | Control Range | Control Increment |
IPAP | 0 to 50 cm H2O | 1 cm H2O |
EPAP | 0 to 50 cm H2O | 1 cm H2O |
CPAP | 0 to 50 cm H2O | 1 cm H2O |
Rate | 0 to 150 BPM | 1 BPM |
Exhaled Tidal Volume (VT) | 0 to 4000 ml | 1 ml |
Minute Ventilation (Min Vent) | 0 to 99 L/min | 1 L/min |
Total Leak (Tot Leak) | 0 to 300 L/min | 1 L/min |
Patient Leak(Pt. Leak) | 0 to 300 L/min | 1 L/min |
Peak Inspiratory Pressure (PIP) | 0 to 50 cm H2O | 1 cm H2O |
Percent of Patient Triggered Breaths (Pt. Trig) | 0 to 100% | 1% |
Ti/Ttot | 0 to 100% | 1% |